LUCCA A53 / A53 Mini: Drying Inside of Temp Probe

Tools Needed: Pliers Compressed air 1. Remove the top panel of the machine by removing the single screw in the top panel and lifting it off. 2. Pull the protective cover off of the temp probe, you may need to gently use pliers to pull the casing...

LUCCA A53 Mini / Mini Vivaldi: Removing Steam Boiler Fill Valve

Before doing this, please allow the machine to fully cool off and unplug the machine. Before you can remove the probe you will also need to remove the panels on the machine. Tools required: 15mm wrench To create more room to get your 15mm wrench...

LUCCA A53 Mini: Steam Valve Assembly Replacement

You'll need: - 14mm wrench - 17mm wrench - 19mm wrench - Adjustable wrench - Standard Philips Screwdriver - Flat blade (flathead screwdriver) - Pick You'll need to remove the top and front face panel. Removing all panels is not necessary, but...