Profitec Pro 600: Steam/Hot Water Valve Seal Gasket InspectionUpdated 6 months ago
Tools Needed:
- 21mm crescent wrench or adjustable wrench
- Pick or small prying implement
- PTFE tape aka plumber's tape OR food safe thread sealant
- New plumbing seat (if needed)
1. Open the valve all the way.
2. Using a crescent wrench or adjustable wrench unscrew the valve assembly from the arm. Use a towel to avoid marring the finish on the fitting.
3. With the valve assembly out of the machine, inspect the plumbing seat for debris and clean or replace as necessary. Don't forget to clean inside the arm where the valve closes off the steam/water flow.
4. If the plumbing seat shows defects or obvious signs of wear, it will most likely need to be replaced. Use a pick or small prying implement to remove the old seat, be careful not to damage the seat holder.
5. Optional: Apply food-safe thread sealant or 2-3 layers of PTFE tape before reinstalling.