Profitec Move: Coffee Boiler Heating Element Resistance TestUpdated 6 months ago
Tools Needed:
- 2.5mm Allen key (For removing the top panel)
- Multimeter
Steps:
- Unplug the Profitec Move and allow it to cool completely
- Remove the top panel of the Profitec Move. (Link Panel Removal article)
- Disconnect the leads from the Coffee Boiler Heating Element legs.
- Set your multimeter to read resistance/Ohms (Ω). If you do not have an auto-ranging multimeter, set it to read 200 Ω.
- Place one of the multimeter probes on one of the heating element legs and place the other probe on the other element leg. A properly operating heating element in a Profitec Move should have a resistance reading of approximately 18-20 Ω. If your multimeter reads “0” or “OL”, or is significantly higher or lower than 18-20 Ω your heating element has failed and needs to be replaced.