Rancilio Silvia: Resetting the Safety/High Limit SwitchUpdated 6 months ago

If your machine is on but not heating, indicated by the orange power light being on, then this may be a simple solution to get your machine heating up again.

Tools Needed:

  • Phillips screwdriver

1. Remove the top panel by taking out the four screws in the top of the machine.

Rancilio Silvia: Resetting the Safety/High Limit Switch

2. Press in the reset button on the top of the safety switch, if it clicks down then you know it was tripped, and your machine should be able to heat up again.

Rancilio Silvia: Resetting the Safety/High Limit Switch
Was this article helpful?
Yes
No