LUCCA M58 V2: Inspecting Magnet Float and Reservoir Outlet AssemblyUpdated 6 months ago
Tools Needed:
- #2 Phillip's Screwdriver
1. Remove the water reservoir from the machine and identify the magnet float housing.
2. Make sure there are no obstructions to the outlet assembly, and that the metal valve piston can be pressed in and returns to the pictured position.
3. Use the #2 Phillips screwdriver to unscrew the four screws as shown.
4. Remove the outlet assembly from the reservoir and gently pry off the while cap caovering the magnet float.
5. Remove the magnet float and clean out any debris found around the metal piston or the rest of the assembly. Make sure that the magnet float is able to pivot smoothly back and forth.
6. Test the magnet float in a bowl of water to verify that it actually floats before reassembling the reservoir outlet assembly.
7. Make sure that the outlet assembly is correctly oriented when reassembling. The square part of the magnet float needs to point toward the front of the machine when the reservoir is installed.