Clive Coffee logo
Clive Coffee logo

All articles

LUCCA A53 Mini / Mini Vivaldi: Steam Boiler Temperature Sensor Cleaning and ReplacementUpdated 5 months ago

Tools Needed:

  • Phillips Screwdriver
  • 15 mm Wrench
  • Scouring pad or wire bristle brush
  • PTFE tape

1. Remove the panels from the machine by following along with our guide: A53 Panel Removal

2. Disconnect the two wires of the temperature sensor by moving the orange sleeves out of the way and pulling the connecting points apart.

LUCCA A53 Mini / Mini Vivaldi: Removing Steam Boiler Temperature Probe


3. Remove the temp sensor with a 15 mm wrench.

LUCCA A53 Mini / Mini Vivaldi: Removing Steam Boiler Temperature Probe

4. Inspect the temperature sensor for scale build up or obvious wear. Clean or replace, then reinstall.
NOTE: It's a good idea to wrap the threads on the temperature sensor with a few layers of PTFE tape in order to ensure a good seal.
lucca_a53_temp_probe


If necessary, you can find replacement temperature sensors in our web store:
Clive Coffee - La Spaziale Steam Temperature Probe

Was this article helpful?
Yes
No