Tools Needed:
- Flat bladed screwdriver
- Back flush blank
1. Remove the water tank from the machine as you will be tilting it to the side.
2. Tip the machine to the right; the pump is fully inside the machine and will need to be adjusted through an access port on the underside of the machine.

3. Once you've found the access port in the back left corner of the machine, you should be able to reach the pump adjustment screw with a flat bladed screw driver. Turning the adjustment screw clockwise will increase pressure, counterclockwise will decrease pressure.
4.Make half turn adjustments at a time and test machine with a back flush blank to check where pump pressure is at.