Bezzera BZ10: Draining the Boiler (No Heat)Updated 5 months ago
Tools needed:
- 16mm crescent wrench
- bucket or sink
- 2-4 hands
1. Start by removing the panels.
2. Locate the copper tube that attaches to both the boiler and the steam valve:
2. Remove the copper tubing from both sides:
3. Flip the tubing around like so:
4. At this point you can either carefully bend the copper tubing to a right angle or place a small towel under the tubing to protect the inner components:
5. Open the hot water valve to introduce air into the system:
6. Please use caution for this next step! Pull your machine forward to the end of the bench or counter and tilt it over a bucket or a sink so that the water can drain from the boiler:
You have successfully drained the boiler of your BZ10!